Laserfiche WebLink
4.Where the barrier is composed of hori- and(b)the gate and barrier should have mounted on top of the pool structure,and <br /> zontal and vertical members and the dis- no opening greater than 1/2 inch within the means of access is a ladder or steps, <br /> tance between the tops of the horizontal 18 inches of the release mechanism. then(a)the ladder to the pool or steps <br /> members is less than 45 inches,the hori- should be capable of being secured, <br /> zontal members should be located on the 9. Where a wall of a dwelling serves as locked or removed to prevent access,or <br /> swimming pool side of the fence. Spacing part of the barrier,one of the following (b)the ladder or steps should be surround- <br /> between vertical members should not should apply: ed by a barrier which meets Section 1, <br /> exceed 1-3/4 inches in width. Where there Paragraphs 1 through 9.When the ladder <br /> are decorative cutouts,spacing within the (a)All doors with direct access to the pool or steps are secured, locked, or removed, <br /> cutouts should not exceed 1-3/4 inches in through that wall should be equipped with any opening created should not allow the <br /> width. an alarm which produces an audible warn- passage of a 4-inch diameter sphere. <br /> ing when the door and its screen, if pres- <br /> 5. Where the barrier is composed of hori- ent, are opened.The alarm should sound Section II.Indoor Swimming Pool. <br /> zontal and vertical members and the dis- continuously for a minimum of 30 sec- <br /> tance between the tops of the horizontal onds within 7 seconds after the All walls surrounding an indoor swim- <br /> members is 45 inches or more, spacing door is opened.Alarms should meet the ming pool should comply with Section 1, <br /> between vertical members should not requirements of UL 2017 General- Paragraph 9. <br /> exceed 4 inches. Where there are decora- Purpose Signaling Devices and Systems, <br /> tive cutouts, spacing within the cutouts Section 77. The alarm should have a mini- Section III.Barrier Locations. <br /> should not exceed 1-3/4 inches in width, mum sound pressure rating of 85 dBA at <br /> 10 feet and the sound of the alarm should Barriers should be located so as to prohib- <br /> 6.Maximum mesh size for chain link be distinctive from other household it permanent structures,equipment or sim- <br /> fences should not exceed 1-3/4 inch sounds,such as smoke alarms, telephones, ilar objects from being used to climb the <br /> square unless the fence is provided with and door bells. The alarm should automat- barriers. <br /> slats fastened at the top or the bottom ically reset under all conditions.The <br /> which reduce the openings to no more alarm should be equipped with manual Exemptions <br /> than 1-3/4 inches. means,such as touchpads or switches,to A portable spa with a safety cover <br /> temporarily deactivate the alarm for a sin- which complies with ASTM F1346-91 <br /> 7. Where the barrier is composed of diag- gle opening of the door from either direc- listed below should be exempt from the <br /> onal members,such as a lattice fence,the tion. Such deactivation should last for no guidelines presented in this document. <br /> maximum opening formed by the diagonal more than 15 seconds.The deactivation But, swimming pools, hot tubs,and non- <br /> members should be no more than 1-3/4 touchpads or switches should be located at portable spas with safety covers should <br /> inches. least 54 inches above the threshold of the not be exempt from the provisions of this <br /> 8.Access gates to the pool should comply door. document. <br /> with Section 1, Paragraphs I through 7, (b)The pool should be equipped with a ASTM F1346-91. Standard Performance <br /> and should be equipped to accommodate a power safety cover which complies with Specification for Safety Covers and <br /> locking device. Pedestrian access gates ASTM F1346-91 listed below. Labeling Requirements forAll Covers for <br /> should open outward,away from the pool, Swimming Pools, Spas and Hot Tubs. <br /> and should be self-closing and have a self- (c)Other means of protection, such as <br /> latching device. Gates other than pedestri- self-closing doors with self-latching <br /> an access gates should have a self-latching devices, are acceptable so long as the <br /> device. Where the release mechanism of degree of protection afforded is not less <br /> the self-latching device is located less than the protection afforded by(a)or(b) <br /> than 54 inches from the bottom of the described above. <br /> gate,(a)the release mechanism should be <br /> located on the pool side of the gate at 10.Where an aboveground pool structure <br /> least 3 inches below the top of the gate is used as a barrier or where the barrier is <br /> 7 <br />