(14) Floor f 1�nsbe ohail e installed so that the connec- <br />tion from the drai't diverter to the flue can be made without the use <br />of more than two Forty-five degree elbows. The installation of ninety <br />degree elbows in lateral vent piping is prohibited. <br />(15) Connections of lateral vent pipes to0transite or other <br />Type "B" vents must be made with fittings designed by the vent manu- <br />facturers for this purpose. <br />(16) The installation of dampers or stops in the vent pipe <br />attached to any appliance equipped with a draft diverter is prohibited, <br />• <br />VENTILATION <br />SECTION 20. <br />(1)- Space heaters in public sle"ping quarters for the use <br />of transients, tourist camps, rooming housos, etc., must be of the <br />fully vented type, i.e., having an enclosed combustion chamber and <br />equipped aith draft diverter and vented according to standards set <br />out under the rules provided in Section 19 of this ordinance. <br />(2) No :installer or individual shall install or c^use to be <br />installed a ventilating fan in a r.usidcnce, apartment, hotel, or com- <br />mercial cooking establishment until the following provisions are com- <br />plied with: There shall be pormancntly opened ventilator or opening <br />or series of openings at least oqu^1 in area to the total square inches <br />in the exhaust opening of the fan or fans. <br />(3) 'No gas fired equipment shall be installed in a base- <br />ment, bathroomo or under buildin;s, or within any other Enclosed space <br />unless adequate provision has been modo to admit to the space suffi- <br />cient fresh air to support combustion. The minimum cross sectional <br />area of ventilation required shall be equal to one(1) square inch <br />for every thousand B.T.U. of the total input rating of all appliances <br />installed or operating within the room or c;nclosure. <br />ADJUSTMENTS <br />SECTION 21. <br />(1) Every gas appliance hereafter installed shall be pro- <br />perly adjusted by the person making the installation, and no such <br />appliance, following the installation, shall be left connected to the <br />gas piping unless every reasonable precaution has been employed to <br />insure safe operati-n of the burners and proper combustion of the gas, <br />due attention being given to draft conditions and ventilations., <br />(2) In no case shall an appliance be fired or adjusted to <br />pass a greater amount of gas than the rated capacity. <br />UNAUTIIOR=D DEVICES <br />SECTION 22. <br />No person, firm, or corporatism shall, without the approval <br />of the Inspector, display, sell, barter, replace, offer for sale, lease <br />deal in, supply, rent donate, ognncct, or install within the corpo- <br />rate limits of the �jj �Q,i 'l any device pur- <br />porting to reduce gas nsi pti6n'_-U oil suJ-h-device is tended as an <br />adjunct or addition to a gas appliance,or to be suspended above, or <br />to wholly or partially enclose any burner of a gas appliance in such <br />manner as to reduce the effectiveness of ignition of the gas issuing <br />from the burner or impair combustion of said burner. <br />MAINTEWiN CE <br />SECTION 23., <br />1111 gas piping, vents, vent connections, and appliances <br />shall be maintained in good conditions; provided, however, that no <br />gas piping, vent, vent connection, fixture, or appliance not conform- <br />ing to the requirments of this ordinance shall be used or maintained <br />if the use of maintenance t?iereof would endanger life or property, and <br />no gas appliance shall be operated, which, in the opinion of the <br />Inspector, is not provided with ample ventilation. <br />-9- <br />