My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1995-01-02
CITY-OF-BATESVILLE
>
City Clerk
>
Ordinances
>
1995
>
1995-01-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/3/2016 2:30:07 PM
Creation date
6/3/2016 2:29:42 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
and of any existing cross connections of which the consumer is aware. <br /> ® D. Submit construction plans for approval, obtain a permit and install <br /> P PP p an approved <br /> backflow prevention assembly. Failure, refusal, or inability on the part of the <br /> customer to install, maintain, and have tested, any backflow prevention assembly <br /> on the consumer's property shall constitute grounds for discontinuing water <br /> service until such requirements have been satisfactorily met. <br /> E. Have the type of backflow prevention assembly and manner of installation <br /> approved by the Approving Authority. <br /> F. Install a backflow prevention assembly if a private water source is operational even <br /> if it is not cross connected to the Water System. <br /> G. Install two (2)backflow prevention assemblies in parallel if uninterrupted water <br /> service is desired during testing or repair. <br /> H. Not install a by-pass around any backflow prevention assembly unless there is a <br /> backflow prevention assembly of the same type in the bypass. <br /> I. Have a certified operational test within 10 days of installation. All RPZA's will be <br /> tested at intervals not to exceed one (1) year after installation. All DCVA's will be <br /> • tested at intervals not to exceed once every three (3)years. In those instances <br /> where the approving Authority deems the degree of hazard to be great, an <br /> operational test may be required at more frequent intervals. <br /> J. Have only personnel licensed by the Arkansas State Health Department accomplish <br /> repairs, installation, maintenance and testing of domestic backflow prevention <br /> ' assemblies. Assemblies for fire protection lines tapped from a domestic service <br /> line shall meet the same criteria. Repairs shall be made immediately upon <br /> notification by the tester. Overhaul shall be accomplished at intervals not to <br /> exceed five (5) years. <br /> K. Have only personnel licensed by the Arkansas Fire Protection Licensing Board <br /> accomplish repairs, maintenance, installation and testing of designated fire <br /> protection service line backflow prevention assemblies. <br /> 4.9 RETROFIT <br /> All presently installed backflow prevention assemblies and devices that do not meet the <br /> requirements of this program but were approved assemblies for the purposes described <br /> herein at the time of installation and have been properly maintained, shall, except for the <br /> inspection, testing and maintenance requirements, be excluded from the requirements of <br /> © 17 x <br /> F <br />
The URL can be used to link to this page
Your browser does not support the video tag.