(2) All gfs pipi-n�; 1 '8i.uo buildings must be scaurcly <br />strapped to joists or ceiling with iron dtraps or approved wire hang- <br />ers. No hangers made of nails or wood will be permitted: <br />(3) The use of bushings in any house or yard line is pro- <br />hibited. <br />(4) The use of unions in concealed locations is prohibited. <br />(5) Gas outlets for instantaneous water heaters and gas <br />ranges shall not be less than three fourths (A) inch pipe, and all <br />outlets for central heating plants not less than one (1) inch pipe. <br />(6) All other outlets shall not be less than one half (1/2) <br />inch pipe. <br />(7) All gas outlets shall extend through the floor or base <br />board not less than two and one half (2-1/2) inches. <br />(8) Table of minimum sizes for house piping shall be as <br />f ollows <br />Minimum Size <br />172 <br />3/4 1n'h pipe <br />11 <br />3/ 4 I, „ <br />1 it 1, <br />1 <br />it if <br />1 <br />it <br />1 n n <br />11/4 <br />11/2 <br />11/2 If If <br />2 It it <br />2 It It <br />Maximum <br />Length <br />10 f e e t <br />10 <br />" <br />20 <br />" <br />20 <br />" <br />0 <br />" <br />0 <br />80 <br />" <br />50 <br />,► <br />100 <br />" <br />50 <br />" <br />100 <br />100 <br />' <br />200 <br />If <br />Maximum Number of Outlets <br />6 <br />4 <br />2 <br />1 <br />15 <br />40 <br />20 <br />80 <br />40 <br />(9) Where gas meters are installed above ground at the <br />house, each consumer's service line shall be provided by the gas com- <br />pany with a suitable stop cock located in an accessible place and at <br />the inlet of the meter. <br />(10) Where an underground meter is used, each consumerts <br />house line shall be provided with a suitable stop cock(sill cock) at <br />a point above ground where the gas line enters the building.. <br />1(11) Where more than one meter is supplied through one ser- <br />vice line, a stop cock shall be installed at each meter inlet in <br />addition to the service line stop. <br />(12) The size of house piping not otherwise provided for in <br />this section shall be approved by the Inspector and satisfactory to <br />the gas company. <br />METER LOCATIONS <br />SECTION 15. <br />1'. meter location shall be -provided for the building or pre- <br />mises to be served, and the location shall be such that the meter <br />connections are easily accessible in order that the meter may be road <br />or changed. No gas meter shall be heroaftor i-:stailed under a stoop, <br />stairway, shove window, or porch, or near a furnace, boiler, or other <br />heating; appliance. No moter shall be placed in any other location <br />whero•it will be inaccessible or liable to injury. Locition, dimen- <br />sions, and type of installation shall be designated by the gas company. <br />..5- <br />