Laserfiche WebLink
• (1) Townhouse lots. Submission of a plat creating lots for townhouse residences shall be <br /> accompanied by a generalized site plan showing the proposed location and dimensions of all <br /> buildings, accessory uses and other improvements. Such lots shall be not less than 30 feet in <br /> width by 80 feet in depth, and with overall size of 2,400 square feet. Platted building lines shall <br /> conform to the building location shown in the generalized site plan. <br /> (2) Zero-lot-line residential lots. Submission of a plat creating a zero-lot-line development, where <br /> permitted, shall be accompanied by a generalized site plan showing the proposed locations and <br /> dimensions of all buildings, accessory uses and other improvements. Inside the city, such lots <br /> shall conform to the requirements of the zoning district whithin which they are located. <br /> Outside the city, such lots shall be not less than 50 feet wide by 90 feet in depth and with a <br /> minimum overall size of 4,500 square feet. Platted building lines shall be shown on all sides of <br /> each lot. Platted building lines shall conform to the building locations shown on the <br /> generalized site plan. <br /> (c) No residential lot shall be more than three times as deep as it is wide except lots designated for <br /> townhouse or zero-lot-line use or average less than 100 feet in depth. Lot width shall be measured at <br /> the building line except in the case of lots abutting a cul-de-sac, where the average width of the lot <br /> shall be used. <br /> (d) Lots served by a public water system and proposed to be served by a septic tank system shall submit <br /> at the time of preliminary plat filing a written certification of approval by the health department. <br /> The lot sizes allowable by this certification shall be indicated on the plat. <br /> • (e) Where a subdivision abuts or contains an existing or proposed arterial street, freeway, expressway or <br /> railroad right-of-way, the planning commission may require double-frontage and reversed-frontage <br /> lots as a means of providing adequate protection of residential development and to afford separation <br /> of land from through traffic. Double-frontage lots may also be used to facilitate residential <br /> development in hillside areas as defined in section 3.12. Elsewhere, double-frontage lots shall be <br /> avoided. <br /> (f) Side lot lines shall be at right angles to street lines or radial to curving street lines unless a variation <br /> from this regulation will give a better street or lot plan or allow better utilization or conservation of <br /> energy. <br /> (g) Corner lots shall have additional width to accommodate the required building line on both streets <br /> and to assure adequate visibility for traffic safety. <br /> (h) Pipe-stem lots may be permitted in residential subdivisions provided that the stem or narrowest part <br /> of such a lot shall not be less than 20 feet in width or have a length of more than 200 feet. <br /> (i) In residential subdivisions where lots abut a freeway, expressway or mainline railroad right-of-way, <br /> such lots shall have an overall depth of not less than 175 feet in order to ensure proper separation of <br /> residences from adjacent thoroughfare or railroad line. <br /> Section 15.03.06. Platted buildine lines and buffers <br /> (a) Building lines for residential lots within the city shall conform to the requirements of the zoning <br /> • district within which they are located. Building lines for residential lots outside the city shall be at <br /> least 25 feet from each street property line except in the following circumstances: <br /> -171 - Batesville Subdivision Regulations <br />