0 the attached slope density table and applying to it the average slope (determined in subsection <br /> (b)of this section). <br /> (2) The allowed units per acre for a particular average percent slope shall be multiplied by the total <br /> acreage of slope area to arrive at a total number of dwelling units allowed. The dwelling units <br /> allowed shall be rounded downward to the next whole unit. Following staff review and <br /> approval of the slope analysis,the subdivider shall prepare a preliminary plat conforming to the <br /> density per acre established and submit it for approval in the conventional manner. <br /> (d) Conformance All hillside areas shall conform to the density requirements determined in the slope <br /> density table. However,the planning commission may increase the allowable units per acre based on <br /> substantial dedications of open space above the minimum requirements and/or dedications of open <br /> space which conform to the parks and open space plan. <br /> (e) Retaining walls Retaining walls may be required wherever topographic conditions warrant or where <br /> necessary to retain fill or cut slopes within the right-of-way. The retaining walls shall be constructed <br /> on private property to protect the streets from possible erosion and slides. Such improvements shall <br /> require the approval of the city. <br /> (f) Rugged areas Hillside areas with an average slope of 40 percent or above are considered extremely <br /> rugged and development shall be limited to lots not less than two acres in size. <br /> (g) Front yard setbacks. Minimum front yard setbacks shall conform to the zoning ordinance except for <br /> areas with slopes in excess of 18 percent,where they may be reduced to 15 feet. <br /> • (h) Cuts and fills. Major cuts, excavation, grading and filling,where they materially change the site and <br /> its relationship with surrounding areas or materially affect such areas, shall not be permitted if such <br /> excavation, grading and filling will result in a slope exceeding a vertical rise of one foot for each 2 <br /> 1/2 feet of horizontal distance between abutting lots(sides and/or rear)or between adjoining tracts of <br /> land, except where adequate provision is made to prevent slides and erosion by cribbing and <br /> retaining walls. Deviation from these standards may be authorized by the planning commission upon <br /> submission of an engineering analysis of the soil conditions and the condition of the compacted fill <br /> showing that the area is suitable for building. <br /> (i) Vehicular access easements. Easements providing primary access to lots fronting on a public street <br /> may be authorized by the planning commission where topographic conditions warrant and where the <br /> public interest can be demonstrated. Where approved, access shall serve not more than five lots nor be <br /> more than 300 feet in length. Pavement shall be of concrete not less than 20 feet in width. Underground <br /> drainage shall be waived by the city when it can be demonstrated that open drainage will accommodate <br /> all runoff. Grades shall not exceed those specified for residential streets. <br /> 0) Soils analysis. The planning commission, at the subdivider's expense, may require a soil test of the <br /> streets and building sites where the suitability of the area for building is questionable. <br /> (k) Drainage. <br /> (1) Stormwater runoff collection facilities shall be designed to retain stormwater runoff on <br /> development sites for a sufficient length of time so as to prevent flooding and erosion during <br /> . stormwater runoff flow periods. <br /> (2) Required storm runoff collection facilities shall be so designed as to divert surface water away <br /> from cut faces or sloping surfaces of a fill. French drains are not acceptable. <br /> - 185 - Batesville Subdivision Regulations <br />